13 research outputs found

    Fast automatic myopic deconvolution of angiogram sequence

    Get PDF
    International audienceWe present a fast unsupervised myopic deconvolution method dedicated to quasi-real time processing of video sequences such as angiograms. Our method is based on a Bayesian approach of which the tuning parameters are automatically set thanks to the marginalized likelihood of the observed image. We demonstrate the effectiveness of our approach on simulated and empirical images

    Characterization of the nanophase precipitation in a metastable beta titanium-based alloy by electrical resistivity, dilatometry and neutron diffraction

    No full text
    The metastable beta Ti-6Mo-5Ta-4Fe (wt.%) alloys was synthesized by cold crucible levitation melting and then quenched in water from the beta phase field. In order to investigate the transformation sequence upon heating, thermal analysis methods such as electrical resistivity, dilatometry and neutron thermodiffraction were employed. By these methods, the different temperatures of transition were detected and solute partitioning was oberved to the beta matrix during the omega and alpha nanophase precipitatio

    Méthodes d'augmentation de résolution en microscopie optique exploitant le modelage de faisceau laser et la déconvolution

    Get PDF
    La microscopie à balayage laser est limitée en résolution par la limite de diffraction de la lumière. Plusieurs méthodes de superrésolution ont été développées depuis les années 90 pour franchir cette limite. Cependant, la superrésolution est souvent obtenue au prix d'une grande complexité (laser de haute puissance pulsé, temps d'acquisition long, fluorophores spécifiques) ainsi que des limitations dans le type d'échantillon observé (observation en surface uniquement). Dans certains cas, comme pour l'illumination structurée et la microscopie SLAM, une amélioration en résolution plus modeste est obtenue, mais avec une complexité et des limites d'utilisation fortement réduites par rapport aux autres méthodes de superrésolution. Les mé- thodes que nous proposons ici sont des méthodes d'augmentation de résolution qui visent à minimiser les contraintes expérimentales et à garder un maximum des avantages des techniques d'imagerie conventionnelles. Dans les cas que nous avons étudiés, les méthodes proposées sont basées sur la microscopie confocale. Nous allons montrer dans un premier temps qu'il est possible d'augmenter de 20% la résolution d'un microscope confocal en changeant le faisceau laser utilisé pour l'excitation par un faisceau Bessel-Gauss tout en ayant un sténopé de la bonne taille (soit 1 Airy Unit). Les avantages de la méthode proposée résident dans sa simplicité d'installation et d'utilisation et sa compatibilité avec d'autres méthodes d'augmentation de résolution. Nous avons démontré les capacités d'augmentation de résolution des faisceaux Bessel-Gauss théoriquement puis exp érimentalement sur des échantillons de nano-sphères et de tissus biologiques obtenant ainsi une résolution de 0.39. Nous avons également montré que l'amélioration en résolution des faisceaux Bessel-Gauss donne une analyse statistique de la colocalisation avec un taux plus faible de faux positifs. Nous avons utilisé des faisceaux Bessel-Gauss de différents ordres pour améliorer la méthode de la microscopie SLAM et ainsi obtenir une résolution descendant à 0.17 (90 nm avec une longueur d'onde de 532 nm). La méthode proposée est entièrement basée sur la microscopie confocale et seul un module permettant de changer le faisceau laser doit être ajouté au montage. Dans un second temps, nous proposons une méthode permettant de bénéficier au maximum des propriétés de la déconvolution pour augmenter la résolution de la microscopie confocale. Pour cela, nous avons utilisé différents modes laser pour l'acquisition d'images et ces images sont utilisées comme données d'entrée pour la déconvolution (avec des mesures des PSF respectives). Les faisceaux laser utilisés apportent ainsi des informations complémentaires à l'algorithme de déconvolution permettant ainsi d'obtenir des images avec une résolution encore meilleure que si une simple déconvolution (utilisant le même algorithme) était utilisée sur l'image confocale. Par la suite, nous avons changé les faisceaux laser par des faisceaux Bessel-Gauss pour augmenter davantage l'ecacité de la déconvolution. Encore une fois, la méthode proposée est entièrement basée sur la microscopie confocale et seul un module permettant de changer le faisceau laser doit être ajouté au montage. Enfin, nous proposons d'aborder une méthode de reconstruction en trois dimensions par tomographie basée sur des projections obtenues en microscopie à deux photons utilisant les faisceaux Bessel-Gauss. En focalisant des faisceaux Bessel-Gauss à angle en microscopie deux photons, on obtient une série de projections utilisables pour une reconstruction tomographique. Le but est de tester la faisabilité de la méthode qui permettrait de reconstruire un volume, en nécessitant moins d'images que dans le cas d'une acquisition plan par plan, en microscopie deux photons classique.Laser scanning microscopy is limited in lateral resolution by the diffraction of light. Superresolution methods have been developed since the 90s to overcome this limitation. However, superresolution is generally achieved at the cost of a greater complexity (high power lasers, very long acquisition times, specic uorophores) and limitations on the observable samples. In some cases, such as Structured Illumination Microscopy (SIM) and Switching Laser Modes (SLAM), a more modest improvement in resolution is obtained with a reduced complexity and fewer limitations. We propose here methods which improve the resolution while minimizing the experimental constraints and keeping most of the advantages of classical microscopy. First, we show that we can improve by twenty percent the resolution of confocal microscopy by using Bessel-Gauss beams, and by having the right pinhole size (1 Airy Unit), compared to conventional Gaussian beam based confocal microscopy. The advantages of this strategy include simplicity of installation and use, linear polarization compatibility, possibility to combine it with other resolution enhancement and superresolution strategies. We demonstrate the resolution enhancement capabilities of Bessel-Gauss beams both theoretically and experimentally on nano-spheres and biological tissue samples with a resolution of 0.39. We achieved these resolutions without any residual artifacts coming from the Bessel-Gauss beam side lobes. We also show that the resolution enhancement of Bessel-Gauss beams leads to a better statistical colocalization analysis with fewer false positive results than when using Gaussian beams. We have also used Bessel-Gauss beams of different orders to further improve the resolution by combining them in SLAM microscopy achieving a resolution of 0.17 (90 nm with a wavelength of 532 nm). In a second step, we propose a method to improve the resolution of confocal microscopy by combining different laser modes and deconvolution. Two images of the same eld are acquired with the confocal microscope using different laser modes and are used as inputs to a deconvolution algorithm. The two laser modes have different Point Spread Functions and thus provide complementary information leading to an image with enhanced resolution compared to using a single confocal image as input to the same deconvolution algorithm. By changing the laser modes to Bessel-Gauss beams, we were able to improve the effciency of the deconvolution algorithm and to obtain images with a residual Point Spread Function having a width smaller than 100 nm. The proposed method requires only a few add-ons to the classic confocal or two photon microscopes. Finally, we propose a three dimensional tomography reconstruction method using Bessel-Gauss beams as projection tools in two-photon microscopy. While focussing Bessel-Gauss beams at an angle in two photon microscopy, we can obtain a series of projections that can be used for tomography reconstruction. The aim is to test the practicality of the methods allowing to reconstruct a volume while using fewer images than plane by plane acquisitions as in classic two-photon microscopy

    Does barrel size influence white wine aging quality?

    No full text
    Article de revue professionnelleLe vin blanc est de plus en plus souvent vieilli en fûts de chêne afin d’améliorer sa stabilité, sa complexité aromatique et ses propriétés organoleptiques. Par conséquent, cette étude avait pour objectif de mettre en évidence les différences chimiques et sensorielles des vins de Sauvignon blanc liées à la taille des fûts. Les paramètres œnologiques, la couleur, les composés phénoliques totaux et l’arôme fruité n’ont, dans l’ensemble, pas été influencés par la taille du fût. En revanche, plus le fût est petit, plus le taux de substances volatiles boisées est élevé. D’un point de vue organoleptique, les arômes et la typicité du Sauvignon blanc semblent mieux conservés dans des fûts de 500 LWhite wine is increasingly aged in oak barrels to enhance its stability, aromatic complexity and organoleptic properties. Thus, this research aimed to highlight chemical and sensory differences in Sauvignon Blanc wines linked to barrel size. Oenological parameters, color, total phenolics and fruity aroma were not generally impacted by barrel size. Meanwhile, the smaller the barrel, the higher the extraction of oak woody volatiles. From an organoleptic point of view, Sauvignon Blanc varietal aromas and typicity seemed to be better preserved by 500 L barrels

    Robust autofocus for digital-holographic microscopy

    No full text
    International audienceA new method to achieve autofocus in digital holography is proposed. It is based on the insertion of calibrated objects in the sample and the use of a robust algorithm to locate these objects

    Automatic numerical focus plane estimation in digital holographic microscopy using calibration beads

    No full text
    International audienceWe present a new method to achieve autofocus in digital holographic microscopy. The method is based on inserting calibrated objects into a sample placed on a slide. Reconstructing a hologram using the inverse problems approach makes it possible to precisely locate and measure the inserted objects and thereby derive the slide plane location. Numerical focusing can then be performed in a plane at any chosen distance from the slide plane of the sample in a reproducible manner and independently of the diversity of the objects in the sample

    Pouvoirs des familles, familles de pouvoir

    No full text
    La famille constitue depuis longtemps un objet d’étude privilégié des historiens des sociétés. Ayant abandonné l’attention presque exclusive accordée autre­fois aux seuls lignages aristocratiques voire royaux, cette histoire de la famille a connu depuis un demi-siècle de profonds renouvellements, tant thématiques que méthodologiques. Directement impliquée dans l’histoire quantitative, notamment par le biais de la « reconstruction des familles », la thématique familiale s’est retrouvée au centre de l’histoire des mentalités. Ultérieurement enfin, via l’importation de problématiques venues des autres sciences sociales et le recours à la démarche « micro-historique », la famille s’est muée en un espace social et anthropologique au sein duquel sont mises à jours les dynamiques qui affectent ces réalités familiales. Dans le même temps, ces réflexions sur le passé d’une réalité sociale toujours vivante viennent en écho aux interrogations contemporaines sur le devenir de la famille nucléaire. La « crise » d’un modèle familial pluriséculaire et les recompositions familiales auxquelles elles donnent lieu placent ces réflexions sur la famille au cœur d’un débat de société particulièrement intense. Dans ce contexte qui fait de la famille un sujet d’actualité brûlant, le colloque organisé à Toulouse a voulu dresser un bilan des travaux les plus récents des meilleurs spécialistes du sujet, il s’est inscrit dans une démarche délibérément comparatiste tout en insistant sur les continuités et les ruptures identifiables tant en termes de problématiques, de démarches que de résultats. Compte tenu de la spécificité du laboratoire à l’origine de cette réflexion, le comparatisme concerne essentiellement les espaces français et ibérique, ce dernier étant compris au sens large puisqu’il intègre les sociétés coloniales ibéro-américaines. Dans le même temps, ce colloque a fait le choix de la transdisciplinarité et de la longue durée, depuis le bas Moyen-Âge jusqu’au xxe siècle. Cette longue phase chronologique coïncide avec l’émergence puis le développement de la structure nucléaire, modèle familial précisément en cours de redéfinition aujourd’hui. À son propos, leurs auteurs y confrontent des approches historiques, sociologiques, anthropologiques et juridiques qui toutes éclairent les complexités de cette histoire tout en contextualisant les interroga­tions contemporaines

    Les stratégies thérapeutiques médicamenteuses et non médicamenteuses de l’aide à l’arrêt du tabac

    No full text
    corecore